 IRt/c.01

Key features:
• Sensing Range: -50 to 550 °F (-45 to 290 °C)
• Ambient Temperature Range: 0 to 160 °F (-18 to 70 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 1:1 (60°) approximately
• Minimum Spot Size: 0.3" (8 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 3 Kohms approximately
• Cable: Thermocouple extension grade, PVC jacket, unshielded
• Dimensions: 1.28" x .71" Diameter (32.5 x 20 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: High strength ABS, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe. Two locknuts supplied.
Get a Quote
 
   
 IRt/c.03

Key features:
• Sensing Range: -50 to 550 °F (-45 to 290 °C)
• Ambient Temperature Range: 0 to 160 °F (-18 to 70 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 3:1 (17°) approximately
• Minimum Spot Size: 0.25" (6 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 4 to 8 Kohms approximately
• Cable: Thermocouple extension grade, PVC jacket, unshielded
• Dimensions: 1.49" x .71" Diameter (37.8 x 20 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: High strength ABS, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe. Two locknuts supplied.
Get a Quote
 
   
 IRt/c

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Ambient Temperature Range: 0 to 212 °F (-18 to 100 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 1:1 (60°) approximately
• Minimum Spot Size: 0.3" (8 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 3 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 1.75" x .50" Diameter (44 x 12.7 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
Get a Quote
 
   
 IRT/c.3X

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 3:1 (17°) approximately
• Minimum Spot Size: 0.25" (6 mm)
• Spectral Response: 6.5 to 14 ĩ (2 to 20 ĩ with IRt/c.3XG germanium lens)
• Output Impedance: 4 to 8 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 1.76" x .50" Diameter (44.7 x 12.7 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
• Air Purge: Built-in; designed for severe paint or ink environment; 3; (0.9 m) of tubing provided.
Get a Quote
 
   
 IRt/c.SV

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Ambient Temperature Range: 0 to 212 °F (-18 to 100 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 1:1 (60°) approximately
• Minimum Spot Size: 0.3" (8 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 3 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 2.27" x .50" Diameter (57.8 x 12.7 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
Get a Quote
 
   
 IRt/c.1X

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Ambient Temperature Range: 0 to 212 °F (-18 to 100 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 1:1 (60°) approximately
• Minimum Spot Size: 0.3" (8 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 3 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 1.43" x .50" Diameter (36 x 12.7 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
Get a Quote
 
   
 IRt/c.3SV

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 3:1 (17°) approximately
• Minimum Spot Size: 0.2" (5 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 4 to 8 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 2.27" x .50" Diameter (44.7 x 12.7 mm)
• Weight: 1.6 oz (44 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
• Air Purge: Built-in; designed for severe paint or ink environment; 3; (0.9 m) of tubing provided.
Get a Quote
 
   
 IRt/c.5

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 5:1 (11°) approximately
• Minimum Spot Size: 0.8" (20 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 4 to 8 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 3.4" x 1.375" Diameter (86 x 35 mm)
• Weight: 6.5 oz (184 g) with cable
• Housing Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
• Air Purge Built-in; cooling capacity to 400 °F (200 °C) ambient; 3; (0.9 m) polyurethane tubing provided
Get a Quote
 
   
 IRt/c.10

Key features:
• Sensing Range: -50 to 1200 °F (-45 to 650 °C)
• Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide)
• Field-of-View: 10:1 (6°) approximately
• Minimum Spot Size: 0.8" (20 mm)
• Spectral Response: 6.5 to 14 ĩ
• Output Impedance: 4 to 8 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (K ONLY), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 3.76" x 1.375" Diameter (96 x 35 mm)
• Weight: 6.5 oz (184 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
• Air Purge: Built-in; cooling capacity to 400 °F (200 °C) ambient; 3; (0.9 m) polyurethane tubing provided
Get a Quote
 
   
 IRt/c.2GJ37C
Special Performance Medical Model

Key features:
• Sensing Range: Human Body Temperature
• Optimum Range Selections: +/- 0.2° C from 35.5 to 39.4° C , +/- 0.3° C from 25 to 40° C
• Field-of-View: 1:1 (60°) approximately
• Minimum Spot Size: 0.16" (4 mm)
• Spectral Response: 2 to 20ĩ
• Output Impedance: 10 Kohms approximately
• Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ēF (200 ēC) continuous service.
• Dimensions: 1.75" x .500" Diameter (44 x 12.7 mm)
• Weight: 1.4 oz (40 g) with cable
• Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
• Air Purge: none
Get a Quote
 
   
 IRt/c.2

Key features:
• Sensing Range: -50 to 2000° F (-45 to 1100° C
• Linear Range: 8 Models per thermocouple type
• Field-of-View: 35° approximately
• Minimum Spot Size: 0.16" (4 mm)
• Output Impedance: 4 to 8 Kohms (varies by model)
• Dimensions: 2.45" x 0.5" Diameter (62 x 13 mm)
• Weight: 1.6 oz (44 g) with cable
• Air Purge: Built-in
Get a Quote
 
   
 IRt/c.07

• Ambient Temperature Range: -4 °F - 158 °F (-20 °C - 70 °C) (internal case temperature)
• Storage Temperature Range: -4 °F - 158 °F (-20 °C - 70 °C)
• Field of View of Sensing Element: 7:1 (distance: spot) approximately 8o inclusive
• Minimum Spot size: 0.75" (19 mm)
• Dominant Spectral Response: 6.5 to 14 μm
• Output Sensor: K type thermocouple
• Impedance: 3.5 – 14 Kohms, varies depending on temperature range
• Emissivity (ε): .90
• Measurement Type: Thermopile
• Resolution: Approximately 0.0003 °C, Johnson Noise
• Update Time: Instantaneous
• Time Constant: 100 milliseconds typically
• Response Time (95% of step change): 300 milliseconds
• Accuracy (Interchangeability): 1% at factory calibration conditions
• Dimensions: 3.25" x 1.18" Dia. (82.5 x 29.97 mm Dia.), M30 x 1.5 thread
• Housing: ABS Black Plastic
• Cable Assembly: 3 feet of unshielded, duplex insulated, type K, 24 AWG, PFA
jacket rated to 392 °F (200 °C) (Shielded cable available upon
request)
• Humidity: Non-Condensing
• Power Requirements: None
• Sealed: Hermetically, exceeds NEMA 4X, IP67
• Weight: Approximately 2.3 oz (65 grams)
Get a Quote View Literature
 
   
 microIRt/c
The World's Smallest and Lowest Cost IRt/cTM

Key features:
• Small Size
• Lowest Cost
• Variety of mounting options
• Self powered
• Air purge (optional)
Get a Quote View Literature
 
   
 microIRt/c.SV

Key features:
• Side view mount
• Self powered
• Small size
• Mounting rings
Get a Quote View Literature
 
   
 micro IRt/c.4

Key features:
• Self powered
• Small size
• Low cost
• Mounting rings
• Air purge available
• 4:1 field of view
• Measure higher temperature ranges
• Repeatable signal
• High interchangeability
• Highly Reliable
Get a Quote View Literature
 
   
 micro IRt/c.4SV

Key features:
• Side view mount
• Self powered
• Small size
• Mounting rings
• Built in Air purge
• 4:1 field of view
• High temperature range with signal output tables available
Get a Quote View Literature
 
   
 IRt/c.01Z

Key features:
• Sensing Range: -50 to 550 °F (-45 to 290 °C)
• Ambient Temperature Range: 0 to 160 °F (-18 to 70 °C)
• Optimum Range Selections: Eight models per K t/c type (see Temperature Selection Guide)
• Field-of-View: 1:1 (60°) approximately
• Minimum Spot Size: 0.3" (8 mm)
• Spectral Response: 6.5 to 14 μ
• Output Impedance: 15 to 40 Kohms approx
• Cable: K type, thermocouple extension grade, PVC jacket, unshielded
• Dimensions: 1.28" x 0.71 Dia. (32.5 x 20.0 mm Dia.)
• Weight: 1.4 oz (40 g) with cable
• Housing: High Strength ABS, hermetically sealed, exceeds NEMA 4X and IP67
intrinsically safe. Two locknuts supplied.
Get a Quote View Literature