|
| |
* Click on an image to enlarge it in a new window * |
| | ELECTROMAGNETIC FLOW METERS-TIDALFLUX 4300 F Solution for partially filled pipes
- Measurement in partially filled pipes up to DN1600 / 64"
- Patented, non-contact level measurement
- Measurement possible down to 10% filling of pipe
The TIDALFLUX 4000 flow sensor with integrated and non-contact capacitive level measuring system provides accurate flow measurement in partially filled pipes. TIDALFLUX is designed to measure reliably between 10% and 100% of the pipe cross section. The integrated level sensors in the liner are in no contact with the liquid and are therefore insensitive against fat and oil floating on the surface. Highlights
- For partially filled pipes in the water and wastewater industry
- Broad diameter range up to DN1600 / 64"
- High abrasion resistance and chemical resistance
- Measurement possible between 10% and 100% filling
- Electrodes for flow measurement are below 10% filling level, therefore no
- blind folding by fat and oil floating on the water surface
- Complete factory calibration - no on-site calibration necessary
Industries
Applications
- For partially filled pipes instead of expensive siphon tube constructions
- Water and wastewater
- Surface water
- Biological and chemical wastewater
| |
| | |
| | ELECTROMAGNETIC FLOW METERS-OPTIFLUX 4040 C 2-Wire EMF 2-wire solution
- 2-wire connection without additional cabling
- As dynamic, reliable and accurate as a 4-wire EMF
- Unimpeded pipe cross-section
- No additional pressure loss
- Minimum conductivity 5 μS/cm
- Intrinsically safe connection
OPTIFLUX 4040 C is an electromagnetic flowmeter in 2-wire technology with the dynamics, reliability and accuracy of a 4-wire EMF. OPTIFLUX 4040 C is suitable for steady or pulsating flows. Highlights
- 2-wire EMF with 4-wire functionality
- Reliable readings even in case of pulsating or fast changing flows due to rapid signal processing
- Low power consumption and operating costs
- Protection classes "I", "e" or "d" selectable by the user during installation
- The only 2-wire electromagnetic flowmeter suitable for conductivities down to 5 μS/cm
Industries
- Chemicals
- Iron, Steel & Metals
- Minerals & Mining
- Pharmaceuticals
- Power Plants
- Pulp & Paper
- Water
- Wastewater
Applications
- Pulsating flows
- For aggressive chemicals
- For products with high solid contens
- Suitable for control loop applications
| |
| | |
| | ELECTROMAGNETIC FLOW METERS-OPTIFLUX 7300 C Non wetted electrodes with high tech ceramic liner
- No insulation of electrodes
- Stable measurement in noisy applications
- Improved safety and hygiene with absolute leak tight design
The OPTIFLUX 7300 combines the advantages of non wetted capacitive electrodes, a ceramic liner and the IFC 300 converter. This electromagnetic flowmeter can be used for noisy applications, low conductivities, mediums tending to form an insulating film, applications with high vibrations, and oxidizing, abrasive and toxic mediums. Instead of conventional electrodes that have a direct contact with the process liquid, OPTIFLUX 7300 has a non-contacting capacitive signal pick-up. The electrodes are designed as large-area capacitor plates, mounted behind the ceramic liner. Because the electrodes have no contact with the medium, unwanted catalytic action with metallic parts is eliminated. A second benefit is that the insulation of electrodes no longer forms a risk. In case of a medium that tends to form a non conductive surface coating on the tube wall, the signal pick up between medium and electrodes will not be interrupted. The smooth and pore free ceramic tube construction does not leak and is CIP / SIP resistant, making it highly suitable for hygienic applications in for example the food & beverage and pharmaceutical industry. It is very hard, non permeable and has an extreme and broad chemical resistance, fulfilling requirements of the chemical industry. The construction of the OPTIFLUX 7300 offers an absolute leak tight solution, because leakage through the liner and leakage along the electrodes is not possible. The IFC 300 converter standardly includes extensive diagnostics of the process and meter and powerful filter settings for stable flow measurements. Highlights
- Ceramic liner with non wetted electrodes
- Excellent chemical and abrasion resistance
- Increased safety and hygiene with absolutely leak tight design
- No metals in contact with the medium
- No insulation of the electrodes
- No wear or corrosion of the electrodes
- Stable flow measurement
- Low conductivities to 0.05 μS/cm
- Fully vacuum resistant
- Insensitive for temperature shocks
- Sterile and hygienic; conformity to FDA requirements
- Excellent long term stability and accuracy
- Alternative for mass flowmeter (for the price of an electromagnetic flowmeter)
Industries
- Chemical
- Food & beverage
- Pharmaceutical
- Paper & pulp
- Wastewater
- Machine building
- Primaries
Applications
- Toxic, aggressive and abrasive mediums
- Emulsions: latex, emulsion paints
- Adhesives
- Organic mass production
- Low conductive mediums: (bio-) alcohols, spirits, glycols, glycerine
- Abrasive slurries
- Water mixed with oil or metallic particles
- Fibrous products
- Oil-based products: vegetable oils
- Dairy products: fat creams, milk, cheese, yoghurt with fruit particles
- Cement
| |
| | |
| | ELECTROMAGNETIC FLOW METERS-BATCHFLUX 5500 C Flowmeter for volumetric filling machines
- High-stability zirconium oxide measuring tube
- Extreme long-term stability
- Most compact and lightweight design in the market
BATCHFLUX 5500 C is the industrial standard for volumetric filling machines. Its zirconium oxide liner guarantees extreme long-term dimensional stability and therefore no change in repeatability of filling volumes over long periods of time. The BATCHFLUX 5500 C is the successor to the BATCHFLUX 5015 C. The BATCHFLUX 5500 C offers some major improvements for the most commenly use sizes: DN10 and DN15. It has a better versatility of applications with a much better performance in difficult applications like fibrous products, hot filling and CIP / SIP processes. Another improvement is that KROHNE has been able to further reduce the dimensions and weight of the flowmeter. It now fits in tighter spaces. The weight of filling machines can be reduced and energy savings are possible. The BATCHFLUX 5500 C has en extreme low energy consumption. For the owner of the filling machine this means lower operation costs. Highlights
- Design enables high speed filling with minimal product loss
- High level of filling accuracy
- Long term reliability due to extreme high dimensional stability
- Low power consumption of only 3 W
- Hygienic construction
- Easy to clean.
- CIP and SIP proof
- Absolutely leak-free stainless steel housing concept (DN10 and DN15)
- Application versatility
- 3A approval, FDA compliance (DN2.5...15)
Industries
- Food & Beverages
- Chemical
- Pharmaceutical
Applications
- Carousel and linear filling machines
- Water
- Soft drinks
- Milk
- Beer
- Fruit juices and other fluids with fibres
- Hot fillings up to 140°C / 284°F
| |
| | |
| | ELECTROMAGNETIC FLOW METERS-WATERFLUX 3070 Water Meter Battery powered electromagnetic water meter
- Battery driven with very low power consumption for remote locations
- Easy installation without straight inlet or outlet lengths
- IP 68 rated signal converter for submersion in flooded chambers
The IFC 070 is a battery powered electromagnetic signal converter designed for use in combination with the WATERFLUX 3000 sensor. It is ideal for remote locations in the water industry where no power connection is available and provides certainty in case of power failure. The strengths of the WATERFLUX 3070 lies in its unique flow sensor construction with a rectangular and reduced cross section and its efficient coil construction. The coils provide a stronger and more homogenous magnetic field, leading to an improved signal to noise ratio. The measurement is therefore independent of the flow profile and measurements are very stable. This results in a very good low flow performance. Because of the unique WATERFLUX flow sensor design, whereby the mean flow velocity and flow profile are optimised within the rectangular and reduced cross section, the additional uncertainty for upstream disturbances is drastically reduced. The water meter can be installed directly after an elbow or reducer in the pipe without straight inlet or outlet lengths. A substantial reduction of inlet and outlet sections means smaller measurement pits. Another major benefit of the rectangular sensor construction is the very low power consumption of the signal converter. It has a long battery lifetime of up to 15 years with two internal batteries and 20 years with an external battery pack. Highlights
- Stand alone water meter with battery lifetime up to 15 years
- Unique rectangular sensor construction results in good low flow performance, a large ratio and very low power consumption
- Large measuring range. High accuracy at peak flows during the day and at low flows during the night
- Certified to OIML R49 class 1 & 2 and MID Annex MI-001Optional verification to MID Annex MI-001 for water meters (Module B and D)
- No inlet or outlet sections required when installed e.g. after an elbow or reducer (MID / OIML R49 certified)
- Installation in any position
- Bi-directional flow measurements
- Submersible in flooded measurement chambers (IP 68 / NEMA 6P)
- Special coating for subsurface installation. No need for measurement chambers
- Rilsan® polymer coating with wide range of drinking water approvals. Reference electrode. No grounding rings needed
- Long term reliability and maintenance free. No moving parts, no wear and no obstruction in the flow
- Optional KGA 42 external datalogger and GSM module for remote data transfer
Industries
- Water abstraction
- Distribution networks
- District metering
- Revenue metering
- Irrigation
- Dewatering
Applications
- Measurement of potable water
- Measurement of raw water and irrigation water
- Checking of pumps and water wells
- Monitoring of distribution networks
- Pipeline leak detection
- Water consumption and billing
| |
| | |
| | Electromagnetic Flowmeters – OPTIFLUX 4000 Sensor Standard solution for the process industry
- Standard flow sensor for the process industry
- For demanding applications: High temperatures, low conductivity, hazardous areas.
- Robust and reliable
The OPTIFLUX 4000 electromagnetic flow sensor is the standard in the process industry and suitable even for demanding applications. Highlights
- Standard device in the process industry
- Robust and reliable
- More than 300,000 units operating in the field
- Works reliably under demanding conditions: High temperatures (up to 180°C / 356°F) and low conductivity (non-water from 1 μS/cm, water from 20 μS/cm)
- Quick and easy to install and operate
- Chemically resistant to alkaline solutions and acids
Industries
- Chemicals
- Pulp & Paper
- Water
- Wastewater
- Minerals & Mining
- Iron, Steel & Metals
- Pharmaceuticals
- Oil & gas
Applications
- For clean liquids
- For slurries and pastes with high solids content
- For abrasive and aggressive products
| |
| | |
| | Electromagnetic Flowmeters – IFC 300 Signal Converter The signal converter with the highest performance
- Diagnostics: Process and device diagnostics, accuracy check
- One signal converter for all applications
- Exceeds requirements of VDI / VDE 2650 and NAMUR NE 107
The electromagnetic signal converter IFC 300 is designed to measure the flow velocity, conductivity, volume and mass flow of electrically conductive liquid media. The signal converter can be combined with any measuring sensor, making it very widely used. In terms of available housing versions, there is a compact variant, in which the signal converter is connected to the measuring sensor, as well as the field, wall-mounted and 19" rack-mounted housing. The electronics plug-in module is identical, regardless of the housing version, providing the same functionality and a standardized operating concept. Highlights
- High measuring accuracy and long-term stability : ±0.15% of measured value ± 1 mm/s
- Optimal zero point stability independent from product properties
- Superior process reliability thanks to standard integrated diagnostics: testing of device functions, check for compliance with specifications and application testing
- Available inputs and outputs: Current output (incl. HART®), pulse/frequency output, status output, control input and current input
- Suitable for both partially filled and fully filled pipelines
- Approved for custody transfer according to OIML R 49 and R 117-1, MI-001 and MI-005 (optional)
- Integrated temperature and conductivity measurement
- Optionally available virtual reference offers cost savings and increased process reliability as grounding electrodes and rings are no longer needed
- One converter for all applications, and thus advantages with regard to procurement, engineering and stock-keeping
Industries
- Water & Wastewater
- Chemicals
- Food & Beverage
- Minerals & Mining
- Pharmaceuticals
- Power plants
- Pulp & Paper
Applications Flow measurement of conductive liquids, acids and bases right down to difficult applications such as:
- Products with low conductivity, high solid content or entrained air
- Inhomogeneous, abrasive and corrosive products
- Rapid product change
- Sudden change in pH value
- Pulsating or turbulent flows
| |